al2logoproductal2logo
  flech PRODUCTS flech AMPLIFIER flech CATV flech ATZ
 
Back
   
a
Amplifier
SS/Cat : 3 a
  a CATV a
    MultiBand a
    Sat-CATV a
SS/Cat : 10
    Serie AMP a
    Serie AMZ a
    Serie APA a
    Serie TLC a
  a Serie ATZ a
SS/Prod : 5
 
         

 

 
 
  flech SERIE ATZ 34
 
a
CATV Indoor Distribution Amplifier / Si-Bipolar Push Pull
 

Models

    ATZ 34   ATZ 32R  
Bandwidth - Forward Path
Bandwidth - Reverse Path
  47 - 862 MHz
5 - 65 MHz
(5-42, 5-30 MHz optional)
  85 - 862 MHz
5 - 65 MHz
(5-42, 5-30 MHz optional)
 
L : 2

FORWARD

    ATZ 34   ATZ 32R  
Gain max.
Gain Accuracy
Gain Control
Gain Slope Control (Equalizer)
Output Level (-60 dB IMD3) (1)
Output Level (CTB,-60dB CENELEC 42ch) (2)
Output Level (CSO,-60dB CENELEC 42ch) (2)
Output Level (XMOD,-60dB CENELEC 42ch) (2)
Hum Modulation
Noise Figure
Input/Output Return Loss (3)
  34 dB
±1 dB
0...-20 dB
0...-18 dB
120@450 MHz - 118@862 MHz
104 dBµV
103 dBµV
100 dBµV
< -70 dBc
7 dB
12 dB
  32 dB
±1 dB
0...-20 dB
0...-18 dB
117@450 MHz - 115@862 MHz
102 dBµV
100 dBµV
97 dBµV
< -70 dBc
7 dB
12 dB
 
L :11

REVERSE

    ATZ 34   ATZ 32R  
Gain
Gain Accuracy
Gain Control
Output Level (-60 dB IMD3) (1)
Noise Figure
Input/Output Return Loss (3)
Number of Outputs
  17 dB
± 1 dB
0...-20 dB
118 dBµV
6 dB
12 dB
1 x One way
1 x Test
  17 dB
± 1 dB
0...-20 dB
118 dBµV
6 dB
12 dB
1 x Two ways and forward path subscribers
only extra (filtered) output port
 
L :7

GENERAL

    ATZ 34   ATZ 32R  
Supply Voltage
Technology
Power Consumption
Screening Factor (4)
Connection Elements
Test Port/Extra Port
Mechanical Protection Category
Operating Environment Temperature
Dimensions
Weight
  230 VAC ±10%
Si-Bipolar Push Pull
6W
> 85 dB
F type
-30 dB
IP54
-10°C...+55°C
195 x 136 x 75 mm
1.5 kg
  230 VAC ±10%
Si-Bipolar Push Pull
6W
> 85 dB
F type
Test: -30 / Modem Output 5-862 MHz
IP54
-10°C...+55°C
195 x 136 x 75 mm
1,5 kg
 
L :10
 
  (1) IMD3 value is defined according to EN50083-5 measurement standard.
(2) 60 dB CTB, CSO, XMOD values are defined according to EN50083-3 standard.
(3) Return loss values are defined according to EN50083-3 measurement standard.
(4) Screening Factor is defined according to EN50083-2 measurement standard.
The product is developed and manufactured according to EN50083-1 in connection with EN60065 safety standards.