al2logoproductal2logo
  flech PRODUCTS flech AMPLIFIER flech CATV flech TLC
 
Back
   
a
Amplifier
SS/Cat : 3 a
  a CATV a
    MultiBand a
    Sat-CATV a
SS/Cat : 10
    Serie AMP a
    Serie AMZ a
    Serie APA a
  a Serie TLC a
    Serie ATZ a
SS/Prod : 5
 
         

 

 
 
  flech TLC 35
 
a
Amplifier CATV TLC 35
 

Model TLC 35

Bandwidth - Forword Path (Switchable at site)
Bandwidth - Reverse Path (Switchable at site)
Power Source
  47 - 862 / 54 - 862 / 85 - 862 MHz
5 - 30 / 5 - 42 / 5 - 65 MHz
30-90 VAC Coaxial Line Powered; Cascaded Use
L : 3

FORWARD

Gain max.
Gain Accuracy
Gain Control
Gain Slope Control
Mid-Stage Equalizer-Fixed
Test Ports
Output Level (1)
CTB
CSO
XMOD
Output Level (1)
CTB
CSO
XMOD
Noise Figure
Group Delay (with 42/54 Diplex Filters)
48.25 - 52.83 MHz
55.25 - 58.83 MHz
61.25 - 64.83 MHz
85 - 86 MHz
Input/Output Return Loss (3)
  35 dB
±0.75 dB
0...-20 dB, Continuous Setting, @Input
0...-20 dB, Continuous Setting, @Input
0, 2, 4, 6, 10, 12, 14, 20 dB with plugin modules
-20 dB, @ Input & Output
Cenelec 42 Ch, EN50083-3, -60 dBc, Each Channel Equal Level
112 dBc
115 dBc
108 dBc
Cenelec 42 Ch, EN50083-3, -60 dBc, with 10 dB Mid-Stage Equalizer
114 dBc
117 dBc
110 dBc
6 dB

max. 30 nSec.
max. 30 nSec.
max. 15 nSec.
max. 10 nSec.
-16 dB
L :21

REVERSE

Module Gain
Total Gain
Gain Loss (@30, 42 & 65MHz)
Gain Control - @Input
Gain Control - @Output
Gain Slope Control - @Output
Test Port
Distortion (1) :
CTB
CSO
XMOD
Input/Output Return Loss (3)
Group Delay :
5-6 MHz
13-14 MHz
29-30 MHz
41-42 MHz
64-65 MHz
Noise Figure
  20 dB
18 dB, with diplex filters
1-2 dB max.
0, 2, 4, 6 dB with fixed value plugin modules
0...-20 dB, continuous setting
0, 2, 4, 6, 8, 10 dB with fixed value plugin modules
-20 dB, @Output
4 Channels, EN50083-3, -60 dBc, Each Channel 40 dBmV Equal Level
-61 dBc
-86 dBc
-78 dBc
> 16 dBuV
(with 42/54 MHz Diplex Filters)
max. 50 nSec.
max. 4 nSec.
max. 20 nSec.
max. 30 nSec.
max. 20 nSec.
7 dB
L :21

GENERAL

Power Source
Power Consumption
Technology
Hum Modulation
Lightning Bolt and Surge Protection
Current Pass - AC
AC Power DirectionEMI Isolation (5-1000MHz) (2)
Operating Environment Temperature
Connection Elements
Underwater Durability
Dimensions
Weight
  30-90 VAC over Coaxial Network
14.5W (including 1.3W for Reverse Amplifier)
GaAs Hybrid Power Doubler
-100 @ 10A dB
All ports, IEEE C62.41 Cat B3 (6kV,3kA)
Typical 10 A, Max. 15 A
Selectable as: from Input, from Output or Loop Through< -100 dB
-40°C...+55°C
Standard 5/8'' - 24 UNEF, optional 3/4'' - 24 UNS (Steel input adapters)
15 psi, during 10 sec. @ 20ûC
190 x 170 x 75 mm
1.6 kg
L :21
 
  (1) CTB/CSO/XMOD values are defined according to EN50083-3 measurement standard.
(2) Screening Factor are defined according to EN50083-2 measurement standard.
(3) Return Loss value is defined according to measurement standard.
The product is developed and manufactured according to EN50083-1 in connection with EN60065 safety standards.